4
• When attaching peripheral units to the PL, be sure the PL’s power cord is
disconnected from the main power supply.
General Specifications
Electrical Specifications
Name Description
T Fan cover System fan inside
U System fan A fan for cooling the PL unit.
V Power connector —
W Power switch AC type only.
Power Supply
DC type AC type
Input Voltage DC24V AC100 to 240V
Rated Voltage DC19.2 to 28.8V AC85 to 264V
Rated Frequency — 50/60Hz
Allowable Frequency
Range
— 47 to 63Hz
Allowable Voltage
Drop
5ms or less
1 cycle or less (Voltage drop
interval must be 1s or more.)
*1
*1 When the total of the expansion slot power and the external load power exceeds 15W, the length of
the allowable voltage drop will be 20ms or less. For details, refer to the graphs below.
Power Consumption 145W or less 145VA or less
In-Rush Current 40A or less
Voltage Endurance
AC1000V 20mA for 1 minute
(
between charging and FG terminals
)
AC1500V 20mA for 1 minute
(
between charging and FG terminals
)
Insulation Resistance
DC500V 10MΩ (min.)
(
between charging and FG terminals
)
DC500V 10MΩ (min.)
(
between charging and FG terminals
)
Bottom
(2 slot type)
T
V
To p
(2 slot type)
W
U
J
Allowable Range
(ms)
20
14
35 40 (W)